A-02Y(L)2Y n x 2 Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1


Reference Standard: A-02Y(L)2Y according to DIN VDE 0816 Part 1
Application:This cable is used in local telephone networks as subscriber cable
Conductor Material: Solid annealed copper conductor
Insulation Material:Foamed PE (02Y)
Laying-up: Star quads in unit stranding
Wrapping Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20¡æ to +50¡æ fixed installation:- 40¡ãC to +70¡æ
Operating Voltage: 225V

Electrical Performance:

Conductor Diameter (mm)

Insulation Resistance of per km at 20 o C

Min. (GOhms)

Conductor Resistance per km loop

Max. (Ohms)

0.6
1.5
100
0.8
1.5
73.2
0.9
10
56.6

Size & Dimensions:

A - 02Y(L)2Y ... x 2 x 0,6 STIII BD
Part No. No.of pairs Outerdiameter
£¨mm£©
Cable Weight
£¨kg/km£©
Copper Weight
(kg/km)
CCL-TC-02Y6P0.6
6
12
130
34
CCL-TC-02Y10P0.6
10
13.5
170
57
CCL-TC-02Y20P0.6
20
16
260
113
CCL-TC-02Y30P0.6
30
18
340
170
CCL-TC-02Y40P0.6
40
20
420
226
CCL-TC-02Y50P0.6
50
21.5
490
283
CCL-TC-02Y70P0.6
70
24
650
396
CCL-TC-02Y100P0.6
100
28
880
565
CCL-TC-02Y150P0.6
150
33
1260
848
CCL-TC-02Y2006P0.6
200
37.5
1640
1131

A - 02Y(L)2Y ... x 2 x 0.8  STIII BD
Part No. No.of pairs Outer diameter
£¨mm£©

Cable Weight
£¨kg/km£©

Copper Weight
(kg/km)
CCL-TC-02Y6P0.8
6
13
160
60
CCL-TC-02Y10P08
10
15
225
101
CCL-TC-02Y20P0.8
20
18.5
360
201
CCL-TC-02Y30P0.8
30
21
490
302
CCL-TC-02Y40P0.8
40
23.5
610
402
CCL-TC-02Y50P0.8
50
26
750
503
CCL-TC-02Y70P0.8
70
29.5
990
704
CCL-TC-02Y100P0.8
100
34
1350
1005
CCL-TC-02Y150P0.8
150
41
2020
1508
CCL-TC-02Y2006P0.8
200
47
2650
2011